# Nothing Between His Head and the Beam: The Control Missing at Coomera
- URL: https://www.whsbrief.com/nothing-between-his-head-and-the-beam-the-control-missing-at-coomera/
- Published: 2026-11-15T22:30:00.000Z
- Updated: 2026-11-16T02:45:51.000Z
- Description: A $225,000 fine over a fatal scissor lift crush at Coomera shows why overhead obstructions need secondary guarding and a written safe system.
- Author: WHS Brief
- Tags: blog

On 1 July 2024 a subcontractor's worker was installing a suspended ceiling at a building project in Coomera. He was working from a scissor lift. As the platform rose his head was trapped between the guardrail and an overhead bulk beam. He died from crush injuries. On 5 November the ceiling installation company was fined $225,000 in the Southport Magistrates Court, against a maximum of $1.5 million. Magistrate Fotheringham described the exposure to risk as completely unnecessary.

### The Hazard Is Above the Platform, Not Below It

When most people think about elevating work platforms they think about falls. Harnesses, guardrails and gates all point downward. Coomera is a reminder that the platform is also a machine that moves a person toward fixed structures. Beams, ducts, sprinkler pipes and slab edges do not move out of the way. The operator's body is usually the thing between the controls and the obstruction.

The court said the company should have fitted the platform with a secondary guarding system. These devices are designed to stop or reverse the platform when the operator is pushed onto the controls or a sensing bar is contacted. The court also said there should have been a safe system of work for operating near overhead obstructions, with training and supervision to match.

Ask yourself:

- Do the EWPs on your sites have secondary guarding fitted and working?
- Is that guarding tested at pre-start or just assumed to be there?
- Has anyone mapped the overhead obstructions in the areas where the platform will be used?
- Do your operators know to slow down and stop well short of a beam before moving in?

### A New Code Says the Same Thing

The timing is worth noting. Tasmania's Code of Practice for elevating work platforms took effect on 21 October 2026\. It covers selection, operation, inspection and maintenance. It also lists the key hazards by name: falls from height, collisions, overturning, entrapment and work near powerlines. Entrapment sits right there on the list.

An approved code can be used as evidence of what is known about a hazard and its controls. That matters well beyond Tasmania. Once a hazard and its control are written into a code, it becomes very hard for any business to argue that the risk was unforeseeable or that the solution was unknown. The Coomera worker died more than two years before that code commenced. The control was still available to the company then.

### Subcontractors Ride the Same Platform

The worker who died was employed by a subcontractor. The company that was prosecuted was the ceiling installer that engaged that subcontractor. That detail should make every head contractor and installer stop and think. Supplying or directing the use of a platform brings a duty about how it is set up and used. It does not matter whose name is on the worker's payslip.

- Who on your site decides which platform is used for a ceiling or services job?
- Who checks that a subcontractor's operators have been trained on crush risk, not just on the controls?
- Who supervises the first lift in a congested ceiling space?

### One Thing to Do This Week

Walk one area where EWPs are working at ceiling height. Look up before you look at the platform. Count the beams, ducts and pipes within reach of the basket. Then ask the operator what would happen if they were pushed forward onto the controls. If the answer depends on luck, the task needs a procedure and the platform needs guarding before the next lift.

If you were asked tomorrow to show the safe system for working under that beam, would you be able to hand over a document or only a description of how careful your people are?